<WRAP half column> | <WRAP half column> | ||
Check that the wiper lip and the nozzle tips are aligned correctly: | Check that the wiper lip and the nozzle tips are aligned correctly: | ||
- | * Open the [[ht500:software-version-v1.1.0-operation-and-commissioning#expert-control-screen|[Expert Control]]] screen and move the print head to the maintenance position. | + | * Open the [[ht500:operation#expert-control-screen|[Expert Control]]] screen and move the print head to the maintenance position. |
* Move the left nozzle 30 mm to the right and 20 mm to the front via the movement control buttons. It should rest directly behind the wiper lip. | * Move the left nozzle 30 mm to the right and 20 mm to the front via the movement control buttons. It should rest directly behind the wiper lip. | ||
* Make sure the lip's upper rim is aligned in the middle of the nozzle's conical tip (see adjacent picture). Adjust the wiper lip if required. | * Make sure the lip's upper rim is aligned in the middle of the nozzle's conical tip (see adjacent picture). Adjust the wiper lip if required. | ||
Line 296: | Line 296: | ||
To find a suitable extrusion temperature: | To find a suitable extrusion temperature: | ||
- Open the //Expert Control// menu.\\ On the right hand side of the screen you will find buttons to choose the extruder (left or right). | - Open the //Expert Control// menu.\\ On the right hand side of the screen you will find buttons to choose the extruder (left or right). | ||
- | - Choose an extruder.\\ After selecting ([Left]/[Right]) the menu is extended. The starting temperature is displayed according to the selected filament profile (see [[ht500:software-version-v1.1.0-operation-and-commissioning#configuration|Configuration]]). | + | - Choose an extruder.\\ After selecting ([Left]/[Right]) the menu is extended. The starting temperature is displayed according to the selected filament profile (see [[ht500:operation#configuration|Configuration]]). |
- Enter the extrusion temperature recommended by the manufacturer via the touchscreen keyboard. The temperature can be increased or decreased in steps of\\ 10 °C (tap [**++**] / [**- -**] once) or 1 °C (tap [**+**] / [**-**] once). | - Enter the extrusion temperature recommended by the manufacturer via the touchscreen keyboard. The temperature can be increased or decreased in steps of\\ 10 °C (tap [**++**] / [**- -**] once) or 1 °C (tap [**+**] / [**-**] once). | ||
- Tap [set] when the desired value is set.\\ The 3D printer will heat to this temperature and then unlock the [extrude] and [retract] buttons. | - Tap [set] when the desired value is set.\\ The 3D printer will heat to this temperature and then unlock the [extrude] and [retract] buttons. | ||
Line 312: | Line 312: | ||
<WRAP half column> | <WRAP half column> | ||
- | [{{:reprap-industrial-v1:gui_expertmenu_2_v110.png?400|Try finding the suitable temperature by directly extruding via the //[[ht500:software-version-v1.1.0-operation-and-commissioning#expert-control-screen|Expert Control]]// screen.}}] | + | [{{:reprap-industrial-v1:gui_expertmenu_2_v110.png?400|Try finding the suitable temperature by directly extruding via the //[[ht500:operation#expert-control-screen|Expert Control]]// screen.}}] |
<WRAP info> | <WRAP info> | ||
INFO | INFO | ||
Line 775: | Line 775: | ||
<WRAP half column> | <WRAP half column> | ||
To find the correct multiplier, open the //Setup// menu at the GUI and choose [Calibrate Extrusion].\\ \\ | To find the correct multiplier, open the //Setup// menu at the GUI and choose [Calibrate Extrusion].\\ \\ | ||
- | A detailed description for ABS filament can be found [[ht500:software-version-v1.1.0-operation-and-commissioning#extruder-calibration|here]].\\ | + | A detailed description for ABS filament can be found [[ht500:operation#extruder-calibration|here]].\\ |
For other materials, the same procedure applies but you have to prepare a G-code for the test print. | For other materials, the same procedure applies but you have to prepare a G-code for the test print. | ||
</WRAP> | </WRAP> | ||
Line 1245: | Line 1245: | ||
exit | exit | ||
- | [[software-version-v1.1.0-operation-and-commissioning#switching-off-the-3d-printer|Shut down]] and [[software-version-v1.1.0-operation-and-commissioning#waking-from-standby|reboot]] the HT500 to establish the alterations. | + | [[operation#switching-off-the-3d-printer|Shut down]] and [[operation#waking-from-standby|reboot]] the HT500 to establish the alterations. |
<WRAP clear/> | <WRAP clear/> | ||
==== Use a custom NTP server for time signals ==== | ==== Use a custom NTP server for time signals ==== | ||
Line 1272: | Line 1272: | ||
exit | exit | ||
- | [[software-version-v1.1.0-operation-and-commissioning#switching-off-the-3d-printer|Shut down]] and [[software-version-v1.1.0-operation-and-commissioning#waking-from-standby|reboot]] the HT500 to establish the alterations. | + | [[operation#switching-off-the-3d-printer|Shut down]] and [[operation#waking-from-standby|reboot]] the HT500 to establish the alterations. |