Line 511: Line 511:
  
 === Required tools === === Required tools ===
-  * Allen wrench ​#1.5 +  * open-jaw ​wrench ​size 8 
-  * 2x open-jaw wrench size 8+  * open-jaw wrench size 4
  
 === Additional information === === Additional information ===
 {{anchor:​sg02}} {{anchor:​sg02}}
 [[{|width: 15em}#​Cleaning recommendation|Cleaning recommendation]]\\ [[{|width: 15em}#​Cleaning recommendation|Cleaning recommendation]]\\
-[[{|width: 15em}reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc131|Software manual - filament change]] ​ [[{|width: 15em}reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc14t05|Software manual - expert control]]+[[{|width: 15em}reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc131|Software manual - filament change]]\\  ​[[{|width:​ 15em}reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc14t05|Software manual - expert control]]
  
 <WRAP clear></​WRAP>​ <WRAP clear></​WRAP>​
Line 534: Line 534:
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
-  * Loosen the two set screws ​at the hot end mount with a #1.5 Allen wrench.+  * Loosen the barrel ​set screw at the hot end mount.
 </​WRAP>​ </​WRAP>​
  
 <WRAP half column> <WRAP half column>
-[{{:reprap-industrial-v1:mtc_loosensetscrewheater_2.png?​400|Loosening the hot-end mount set screws ​is mandatory to avoid breaking ​the glued connection of barrel ​and melter.}}]+[{{:ht500:coming_soon.png?​400|Loosening the hot-end mount set screw is mandatory to avoid damaging ​the barrel.}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 548: Line 548:
 NOTICE NOTICE
  
-Do not loosen the nozzle tip without loosening the barrel set screws ​and countering the melter. Distorting the barrel may damage ​the glued connection.\\+Do not loosen the nozzle tip without loosening the barrel set screw and countering the barrel. Distorting the barrel may damage ​it. The barrel must then be replaced.\\
 If solidified material hinders loosening the nozzle tip effortlessly,​ heat up the extruder to the specific extrusion temperature and loosen the tip 2 or 3 turns. **Do not** unscrew the heated tip totally. Dropping the hot nozzle tip will damage the acrylic bottom. If solidified material hinders loosening the nozzle tip effortlessly,​ heat up the extruder to the specific extrusion temperature and loosen the tip 2 or 3 turns. **Do not** unscrew the heated tip totally. Dropping the hot nozzle tip will damage the acrylic bottom.
 Afterwards, turn the extruder off and wait until it has cooled down before completely removing the nozzle. Afterwards, turn the extruder off and wait until it has cooled down before completely removing the nozzle.
 </​WRAP>​ </​WRAP>​
-  * Loosen and remove the nozzle tip with a size 8 wrench while countering with another ​size wrench at the hex section ​of the melter.+  * Loosen and remove the nozzle tip with a size 8 wrench while countering with size wrench at the width flat of the barrel.
 </​WRAP>​ </​WRAP>​
  
 <WRAP half column> <WRAP half column>
-[{{:reprap-industrial-v1:sg_loosennoozletip_marked.png?​400|Unscrewing and fastening the nozzle tip requires attention not to overwinde and sheer off the thread.}}]+[{{:ht500:coming_soon.png?​400|Unscrewing and fastening the nozzle tip requires attention not to overwinde and sheer off the thread.}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 567: Line 567:
 NOTICE NOTICE
   ​   ​
-Overtightening the nozzle tip may shear off the thread. Distorting the barrel may damage the glued connection of the barrel and the melter.\\ **Do not** fasten the nozzle tip without countering.+Overtightening the nozzle tip may shear off the thread. \\ **Do not** fasten the nozzle tip without countering.
 </​WRAP>​ </​WRAP>​
   * Carefully fasten the nozzle tip with a size 8 wrench while countering with another size 8 wrench at the melter.   * Carefully fasten the nozzle tip with a size 8 wrench while countering with another size 8 wrench at the melter.
Line 590: Line 590:
 === Additional information === === Additional information ===
 {{anchor:​sgc03}} {{anchor:​sgc03}}
-  * [[reprap-industrial-v1:​service-guide#​cleaning-recommendation|Cleaning recommendation]] +  * [[ht500:​service-guide#​cleaning-recommendation|Cleaning recommendation]] 
-  * [[reprap-industrial-v1:​knowledge-base#​materials|Knowledgebase]]+  * [[ht500:​knowledge-base#​materials|Knowledgebase]]
   * Software manual: [[reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc131|filament change]]   * Software manual: [[reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc131|filament change]]
-  * Troubleshooting:​ [[reprap-industrial-v1:​troubleshooting#​p1c9|P1]]+  * Troubleshooting:​ [[ht500:​troubleshooting#​p1c9|P1]]
  
 === Deinstalling the barrel === === Deinstalling the barrel ===
Line 599: Line 599:
 <WRAP half column> <WRAP half column>
   * [[#​removing-the-nozzle-tip|Remove the nozzle tip]] as described above.   * [[#​removing-the-nozzle-tip|Remove the nozzle tip]] as described above.
-  * With both set screws ​loosened, carefully push the barrel to the limit up the nozzle seat. +  * With the set screw loosened, carefully push the barrel to the limit up the nozzle seat. 
-  * Fixate the barrel by fastening ​one of the set screws.+  * Fixate the barrel by fastening the set screw.
 </​WRAP>​ </​WRAP>​
  
 <WRAP half column> <WRAP half column>
-[{{:reprap-industrial-v1:mtc_pushbarrelup.png?​400|Push the barrel up to the limit and refasten ​one set screw}}] +[{{:ht500:coming_soon.png?​400|Push the barrel up to the limit and refasten the set screw}}]
-</​WRAP>​ +
-</​WRAP>​ +
- +
-<WRAP group> +
-<WRAP half column>​ +
-  * Loosen ​the set screw of the heating block with a #1.5 Allen wrench. +
-</​WRAP>​ +
-<WRAP half column>​ +
-[{{:​reprap-industrial-v1:​mtc_loosensetscrewheater.png?​400|Loosening heating block set screw.}}]+
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 623: Line 614:
  
 <WRAP half column> <WRAP half column>
-[{{:reprap-industrial-v1:mtc_pullheateroff.png?​400|Pulling the heating block off the barrel.}}]+[{{:ht500:coming_soon.png?​400|Pulling the heating block off the barrel.}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
  
-<WRAP note> 
-<WRAP group> 
-<WRAP half column> 
-NOTICE 
- 
-**Do not** try to pull the heater off without pushing the barrel up.\\ The heating resistor'​s cable may be damaged otherwise. 
-</​WRAP>​ 
- 
-<WRAP half column> 
-{{ :​reprap-industrial-v1:​mtc_heatercablewarning.png?​200 |}} 
-</​WRAP>​ 
-</​WRAP>​ 
-</​WRAP>​ 
  
 <WRAP group> <WRAP group>
Line 647: Line 625:
  
 <WRAP half column> <WRAP half column>
-[{{:reprap-industrial-v1:mtc_pullbarrelout.png?​400|Pull the barrel out of its seat.}}]+[{{:ht500:coming_soon.png?​400|Pull the barrel out of its seat.}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 657: Line 635:
 <WRAP half column> <WRAP half column>
 Install the **left** extruder nozzle first: Install the **left** extruder nozzle first:
-  * Carefully push the barrel to the limit up the nozzle seat and fixate it by fastening ​one set screw. +  * Carefully push the barrel to the limit up the hot-end mount and fixate it by fastening ​the set screw. 
-  * Slip the heating block onto the melter up to the hex section and fasten the set screw tightly. +  * Slip the heating block onto the barrel.
-</​WRAP>​ +
-<WRAP half column>​ +
-{{anchor:​sgc333}} +
-<WRAP info> +
-INFO +
- +
-//A sheer metal surface of the heating block'​s bore and soundly fastening the set screw are vitally important for the heat transfer from heating block to melter.\\ Prior to installation check the inner surface of the bore. If required, refasten the set screw after shortly heating the hot-end to extrusion temperature to soften plastic seeped into the thread.// +
-</​WRAP>​ +
-</​WRAP>​ +
-</​WRAP>​ +
- +
-<WRAP group> +
-<WRAP half column>+
   * Loosen the set screw and lower the barrel until its upper end is level with the hot-end mount'​s upper rim.   * Loosen the set screw and lower the barrel until its upper end is level with the hot-end mount'​s upper rim.
-  * Fasten the two set screws with a #1.5 Allen wrench.+  * Fasten the set screw.
   * Install the **right** extruder nozzle in the given order but a little above the left hot-end.   * Install the **right** extruder nozzle in the given order but a little above the left hot-end.
   * Run the [[reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc13t11|Print Bed Leveling]] wizard.   * Run the [[reprap-industrial-v1:​software-version-v1.1.0-operation-and-commissioning#​omc13t11|Print Bed Leveling]] wizard.
Line 685: Line 650:
 //The barrel'​s upper rim and the recess are suitable indicators for the correct height (compare pictures below).// //The barrel'​s upper rim and the recess are suitable indicators for the correct height (compare pictures below).//
 </​WRAP>​ </​WRAP>​
-[{{:reprap-industrial-v1:mtc_aligningbarrel.png?300|Aligning the extruder barrel and the hot end mount'​s upper rim.}}] +[{{:ht500:coming_soon.png?400|Aligning the extruder barrel and the hot end mount'​s upper rim.}}] 
-[{{:reprap-industrial-v1:mtc_aligningbarrelhigh.png?300|Barrel pushed up too far into its seat (exaggerated).}}] +[{{:ht500:coming_soon.png?400|Barrel pushed up too far into its seat (exaggerated).}}] 
-[{{:reprap-industrial-v1:mtc_aligningbarrellow.png?300|Barrel too low in its seat (exaggerated).}}]+[{{:ht500:coming_soon.png?400|Barrel too low in its seat (exaggerated).}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
 <WRAP clear></​WRAP>​ <WRAP clear></​WRAP>​
  
-==== Cooling water pump ====+==== Refilling the cooling circuit ​==== 
 +Temperature fluctuation cannot be avoided due to the operating conditions of the HT500. The different thermal expansion of the materials causes minimal leakage at the cooling circuit'​s connections which makes refilling the circuit necessary approximately every four weeks. To refill the coolant circuit, follow the instructions given below.
  
 === Required tools === === Required tools ===
Line 698: Line 664:
   * Allen wrench #2.5   * Allen wrench #2.5
 ¹<wrap lo> Order directly via [[sales@kuehlingkuehling.de]],​ the manufacturer'​s webshop (http://​innovatek.de,​ manufacturer part number: 500473) or related distributors.</​wrap>​ ¹<wrap lo> Order directly via [[sales@kuehlingkuehling.de]],​ the manufacturer'​s webshop (http://​innovatek.de,​ manufacturer part number: 500473) or related distributors.</​wrap>​
-=== Demounting and refilling ===+ 
 +=== Checking the cooling circuit === 
 +<WRAP note> 
 +NOTICE 
 + 
 +Lack of coolant may lead to damage of the affected components, especially the LEDs. Too much air in the cooling circuit leads to clogging of the copper connectors due to oxidation.\\ 
 +Check the cooling circuit regularly for excess amounts of gas bubbles. 
 +</​WRAP>​ 
 + 
 +The amount of gas bubbles in the cooling circuit is the indicator for refilling. A small amount of bubbles always circles the hoses and can be considered normal. 
 +To asses whether the cooling circuit must be refilled, check the following:​ 
 +  * The bubbles are small and running freely -> there is no need for refilling the cooling circuit. 
 +  * Bubbles reach the size of the hose's diameter, are sticking in places and do not disappear a few minutes after switching the build chamber on -> refill as described below. 
 + 
 +=== Demounting and refilling ​the pump ===
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
Line 714: Line 694:
 <WRAP half column> <WRAP half column>
 [{{:​reprap-industrial-v1:​mtc_coolingwaterpump_1.png?​400|Cooling water pump mounted in the electronic chamber.}}] [{{:​reprap-industrial-v1:​mtc_coolingwaterpump_1.png?​400|Cooling water pump mounted in the electronic chamber.}}]
-[{{:reprap-industrial-v1:mtc_echamberbackview.png?​400|Holding screws of cooling water pump.}}]+[{{:ht500:mtc_coolingwaterpumpmount.png?​400|Holding screws of cooling water pump at the rear cover of the electronic chamber.}}]
 <WRAP clear></​WRAP>​ <WRAP clear></​WRAP>​
-[{{:reprap-industrial-v1:​mtc_coolingwaterpumpopenlid.png?​400|Opening/​closing the pump's lid.}}] +[{{:ht500:​mtc_coolingwaterpumpopenlid.png?​400|Opening/​closing the pump's lid.}}] 
-[{{:reprap-industrial-v1:​mtc_coolingwaterpumprefill.png?​400|Level indication of the cooling water pump.}}]+[{{:ht500:​mtc_coolingwaterpumprefill.png?​400|Level indication of the cooling water pump.}}]
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 918: Line 898:
  
  
-==== Increasing the minimum detail resolution of the Slic3r ==== 
- <​WRAP group> 
-<WRAP half column> 
-  - Open your Slic3r in "​Expert"​ mode. 
-  - Open the "Print Settings"​ tab. 
-  - Choose "​Advanced"​. 
-  - Type the required resolution into the input field "​Resolution"​ in the "​Other"​ frame. We recommended setting the resolution to a value of ''​0.05''​. 
-<WRAP clear></​WRAP>​ 
-</​WRAP>​ 
  
-<WRAP half column> 
-[{{:​reprap-industrial-v1:​slic3r_minimumres.png?​400|}}] 
-<WRAP info> 
-INFO 
- 
-//​Increasing the value can help solving the problem of blob formation. As a standard the value is set to "​0"​ since it may cause problems with support structures.//​ 
-</​WRAP>​ 
-</​WRAP>​ 
-</​WRAP>​ 
ht500/service-guide.1460121934.txt.gz · Last modified: 2016/04/08 13:25 by Simon Kühling