User Tools

Site Tools


reprap-industrial-v1:troubleshooting

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
reprap-industrial-v1:troubleshooting [2015/11/02 09:02]
Markus Bürgener [Electronic, network, communication]
reprap-industrial-v1:troubleshooting [2015/11/02 09:04]
Markus Bürgener [Error messages]
Line 78: Line 78:
 |< 100% 4% 25% 27% 27% 17% >| |< 100% 4% 25% 27% 27% 17% >|
 ^  No.   ​^ ​ Symptom ​ ^  Possible cause(s) ​ ^  To do  ^  Additional information ​ ^ ^  No.   ​^ ​ Symptom ​ ^  Possible cause(s) ​ ^  To do  ^  Additional information ​ ^
-|  {{anchor:​s1:​S1}} ​ | Profile names are not readable in Slic3r drop-down menus. ​ | Incompatibility of Slic3r (v1.1.7) and Windows operating software. ​ | ✔ Rename profiles with shorter description.\\ ✔ Upgrade to higher version of Slic3r. ​ | [[reprap-industrial-v1:​tips-tricks#​Profile display problems in Slic3r for Windows|Tips&​Tricks]],\\ [[http://​slic3r.org/​download|Slic3r]] ​ | +|  {{anchor:​s1:​S1}} ​ | Profile names are not readable in Slic3r drop-down menus. ​ | Incompatibility of Slic3r (v1.1.7) and Windows operating software. ​ | ✔ Rename profiles with shorter description.\\ ✔ Upgrade to higher version of Slic3r. ​ | [[{|width:​10em}reprap-industrial-v1:​tips-tricks#​Profile display problems in Slic3r for Windows|Tips&​Tricks]]\\ [[{|width:​10em;​color:​green}http://​slic3r.org/​download|Slic3r]] ​ | 
-|  {{anchor:​s2:​S2}} ​ | Crashing of Slic3r with STL-file. ​ | STL-file corrupted\\ see [[#P8]] also  | ✔ Check the STL-file for holes, intersections,​ misaligned edges and the like. Repair or redesign if necessary. ​ | [[reprap-industrial-v1:​tips-tricks#​suitability-check-of-.stl-data|Tips&​Tricks]] ​ |+|  {{anchor:​s2:​S2}} ​ | Crashing of Slic3r with STL-file. ​ | STL-file corrupted\\ see [[#P8]] also  | ✔ Check the STL-file for holes, intersections,​ misaligned edges and the like. Repair or redesign if necessary. ​ | [[{|width:​10em}reprap-industrial-v1:​tips-tricks#​suitability-check-of-.stl-data|Tips&​Tricks]] ​ |
  
  
Line 88: Line 88:
 Use the below list if an ERROR message appears in your log file and you are unsure about its meaning and effects. Use the below list if an ERROR message appears in your log file and you are unsure about its meaning and effects.
 ^  No.  ^ Message ​ ^  Possible cause(s)/\\ effects ​ ^  To do  ^  Further information ​ ^ ^  No.  ^ Message ​ ^  Possible cause(s)/\\ effects ​ ^  To do  ^  Further information ​ ^
-|  {{anchor:​em1:​EM1}} ​ | ''​Printer set into dry run mode until restart!''​\\ <wrap lo>​followed by internal test (example):​\\ //extruder 0: temp sensor defect//\\ //extruder 1: working//\\ //extruder 2: working//\\ //heated bed: working//</​wrap>​ | The named thermistor measured a limit value derivation. The measured temperature exceeded/​came below the allowable limit value.\\ \\ All heating elements are switched off. Extrusion may stop mid-print. ​ | ✔ Check cable connections of the thermistors for damage or wear.\\ If the fragile cables of the thermistor are broken, the heating unit must be replaced.\\ see [[#p9|P9]] also | Limit values are:\\ 0 … 300 °C\\ [[reprap-industrial-v1:​service-guide#​dissemblingre-installing-the-hot-end-nozzle-tips-andor-barrels|Service guide]]\\ \\ Request a quote for the fully assembled replacement part via [[sales@kuehlingkuehling.de]] |+|  {{anchor:​em1:​EM1}} ​ | ''​Printer set into dry run mode until restart!''​\\ <wrap lo>​followed by internal test (example):​\\ //extruder 0: temp sensor defect//\\ //extruder 1: working//\\ //extruder 2: working//\\ //heated bed: working//</​wrap>​ | The named thermistor measured a limit value derivation. The measured temperature exceeded/​came below the allowable limit value.\\ \\ All heating elements are switched off. Extrusion may stop mid-print. ​ | ✔ Check cable connections of the thermistors for damage or wear.\\ If the fragile cables of the thermistor are broken, the heating unit must be replaced.\\ see [[#p9|P9]] also | Limit values are:\\ 0 … 300 °C\\ [[{|width:​10em}reprap-industrial-v1:​service-guide#​dissemblingre-installing-the-hot-end-nozzle-tips-andor-barrels|Service guide]]\\ \\ Request a quote for the fully assembled replacement part via [[sales@kuehlingkuehling.de]] |
 <WRAP clear></​WRAP>​ <WRAP clear></​WRAP>​
  
reprap-industrial-v1/troubleshooting.txt · Last modified: 2017/01/18 09:52 by Simon Kühling