This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revision Both sides next revision | ||
reprap-industrial-v1:troubleshooting [2015/11/02 09:04] Markus Bürgener [Error messages] |
reprap-industrial-v1:troubleshooting [2015/11/02 09:05] Markus Bürgener [Error messages] |
||
---|---|---|---|
Line 88: | Line 88: | ||
Use the below list if an ERROR message appears in your log file and you are unsure about its meaning and effects. | Use the below list if an ERROR message appears in your log file and you are unsure about its meaning and effects. | ||
^ No. ^ Message ^ Possible cause(s)/\\ effects ^ To do ^ Further information ^ | ^ No. ^ Message ^ Possible cause(s)/\\ effects ^ To do ^ Further information ^ | ||
- | | {{anchor:em1:EM1}} | ''Printer set into dry run mode until restart!''\\ <wrap lo>followed by internal test (example):\\ //extruder 0: temp sensor defect//\\ //extruder 1: working//\\ //extruder 2: working//\\ //heated bed: working//</wrap> | The named thermistor measured a limit value derivation. The measured temperature exceeded/came below the allowable limit value.\\ \\ All heating elements are switched off. Extrusion may stop mid-print. | ✔ Check cable connections of the thermistors for damage or wear.\\ If the fragile cables of the thermistor are broken, the heating unit must be replaced.\\ see [[#p9|P9]] also | Limit values are:\\ 0 … 300 °C\\ [[{|width:10em}reprap-industrial-v1:service-guide#dissemblingre-installing-the-hot-end-nozzle-tips-andor-barrels|Service guide]]\\ \\ Request a quote for the fully assembled replacement part via [[sales@kuehlingkuehling.de]] | | + | | {{anchor:em1:EM1}} | ''Printer set into dry run mode until restart!''\\ <wrap lo>followed by internal test (example):\\ //extruder 0: temp sensor defect//\\ //extruder 1: working//\\ //extruder 2: working//\\ //heated bed: working//</wrap> | The named thermistor measured a limit value derivation. The measured temperature exceeded/came below the allowable limit value.\\ \\ All heating elements are switched off. Extrusion may stop mid-print. | ✔ Check cable connections of the thermistors for damage or wear.\\ If the fragile cables of the thermistor are broken, the heating unit must be replaced.\\ see [[#p9|P9]] also | Limit values are:\\ 0 … 300 °C\\ [[{|width:10em}reprap-industrial-v1:service-guide#changing-the-hot-end-barrels|Service guide]]\\ \\ Request a quote for the fully assembled replacement part via [[sales@kuehlingkuehling.de]] | |
<WRAP clear></WRAP> | <WRAP clear></WRAP> | ||