vp75:safety [2016/12/05 20:15]
Markus Bürgener ↷ Links adapted because of a move operation
vp75:safety [2016/12/05 20:20]
Markus Bürgener [Product reliability]
Line 55: Line 55:
 The supply voltage of the VP75 is 230 V(DC). It is reduced and distributed to 12 V and 5 V operating voltages by the power supply unit.\\ The supply voltage of the VP75 is 230 V(DC). It is reduced and distributed to 12 V and 5 V operating voltages by the power supply unit.\\
 All current carrying parts are adequately isolated and encapsuled in the electronic compartment in the upper service chamber of the machine.\\ All current carrying parts are adequately isolated and encapsuled in the electronic compartment in the upper service chamber of the machine.\\
-To switch of current during normal operation, the machine is equipped with a main switch on the rear side.\\ +To switch of current during normal operation, the machine is equipped with a main switch on the rear side.
- +
-**Additional information**\\ +
-[[{:​}:​vp75:​description|Electronic compartment]] [[{:​}:​vp75:​additional-documentation|Electric circuit diagram]] ​+
  
 ==== Emergency stop ==== ==== Emergency stop ====
Line 73: Line 70:
 When the emergency stop is triggered, the microcontroller board responsible for the stepper motors, heaters and sensors is reset immediately and returns to idle state afterwards. Now it is safe to resolve any problems or defects in the build chamber.\\ When the emergency stop is triggered, the microcontroller board responsible for the stepper motors, heaters and sensors is reset immediately and returns to idle state afterwards. Now it is safe to resolve any problems or defects in the build chamber.\\
 \\ \\
-The build chamber can then be reactivated via the [[:software-version-v1.1.0-operation-and-commissioning#​print-screen|[Print] ]] menue.\\ Detailed information are provided in the [[:software-version-v1.1.0-operation-and-commissioning#​emergency-stop|Operating ​manual]].+The build chamber can then be reactivated via the [[:vp75:operation#​print-screen|[Print] ]] menue.\\ Detailed information are provided in the [[:vp75:operation|Operating ​Manual]].
 </​WRAP>​ </​WRAP>​
  
Line 111: Line 108:
 During normal operation it is not necessary to wear special protective gear. Some tasks however should not be performed without taking protective measures. Situations that require protective equipment are specially indicated. It is the owner'​s obligation to provide adequate protective equipment. During normal operation it is not necessary to wear special protective gear. Some tasks however should not be performed without taking protective measures. Situations that require protective equipment are specially indicated. It is the owner'​s obligation to provide adequate protective equipment.
  
-===== Product reliability ===== 
-False handling of components can lead to loss of production due to property damage; therefore we strongly recommend following the information given in this manual. 
  
-=== Extruder nozzles ===+ 
 +==== Extruder nozzles ​====
 The extruder nozzle is sensitive to heat treatment and mechanical strain.\\ If the nozzle or extruder barrel are clogged by congealed material, reheating during the normal production flow is utterly sufficient to clear them in most cases.\\ In case you want to change the material type or clogging is effected by foreign particles (i.e. dust grains dragged along with the filament), it is necessary to remove congealed material from the nozzle. The corresponding description can be found in the [[#Cleaning recommendation|cleaning recommendation]]. The extruder nozzle is sensitive to heat treatment and mechanical strain.\\ If the nozzle or extruder barrel are clogged by congealed material, reheating during the normal production flow is utterly sufficient to clear them in most cases.\\ In case you want to change the material type or clogging is effected by foreign particles (i.e. dust grains dragged along with the filament), it is necessary to remove congealed material from the nozzle. The corresponding description can be found in the [[#Cleaning recommendation|cleaning recommendation]].
 <WRAP clear></​WRAP>​ <WRAP clear></​WRAP>​
vp75/safety.txt · Last modified: 2017/03/14 14:25 by Simon Kühling