This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
vp75:technical-data [2016/12/03 10:59] Markus Bürgener |
vp75:technical-data [2017/01/18 09:21] Simon Kühling correct build sheet size |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Technical Data VP75 AMS ===== | + | ===== Technical Data VP75 Additive Manufacturing System ===== |
==== General / Dimensions / Weights ==== | ==== General / Dimensions / Weights ==== | ||
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
Line 6: | Line 6: | ||
| Additional features | integrated LED lighting | | | Additional features | integrated LED lighting | | ||
| Length | 800 mm | | | Length | 800 mm | | ||
- | | Width | 600 mm | | + | | Width | 800 mm | |
- | | Height | 800 mm | | + | | Height | 2,200 mm | |
| Weight | 250 kg (empty) | | | Weight | 250 kg (empty) | | ||
| Positioning System | 3-axis delta\\ Automatic three-point leveling | | | Positioning System | 3-axis delta\\ Automatic three-point leveling | | ||
| Manufacturing Technology | Fused Filament Fabrication (FFF) | | | Manufacturing Technology | Fused Filament Fabrication (FFF) | | ||
- | | Compressed Air | | + | | Compressed Air | 6-8 bar, dry, oil-free | |
| Connection cable | 1 m\\ 230 V AC Schuko plug\\ IEC 60320 16A connector | | | Connection cable | 1 m\\ 230 V AC Schuko plug\\ IEC 60320 16A connector | | ||
| Network | Ethernet 10/100, RJ45 | | | Network | Ethernet 10/100, RJ45 | | ||
Line 18: | Line 18: | ||
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
| Extrusion Temperature | max. +500°C | | | Extrusion Temperature | max. +500°C | | ||
- | | Build Plate Temperature | max. +130°C | | + | | Build Plate Temperature | max. +150°C | |
- | | Build Chamber Temperature | max. +70°C | | + | | Build Chamber Temperature | max. +80°C | |
- | + | ||
- | + | ||
- | === Hot end === | + | |
- | |<75% 40% 25% 35%>| | + | |
- | | Screwable M6 brass nozzles A/F8 \\ (included in delivery) | Bore diameter\\ [mm] | Recommended layer height\\ First layer / following | | + | |
- | |::: | 2x0.25 | 0.25 / 0.10 - 0.20 | | + | |
- | |::: | 2x0.35 | 0.35 / 0.10 - 0.28 | | + | |
- | |::: | 1x0.50 | 0.50 / 0.20 - 0.40 | | + | |
- | |::: | 1x0.75 | 0.60 / 0.25 - 0.60 | | + | |
=== Building Capacities === | === Building Capacities === | ||
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
- | | Build Volume | 75 liter\\ Height: 400 mm\\ Build plate diameter: 600 mm | | + | | Build Volume | 75 liter\\ Height: 600 mm\\ Build plate diameter: 400 mm | |
| Extruder head | Encapsulated high-temperature single nozzle\\ | | | Extruder head | Encapsulated high-temperature single nozzle\\ | | ||
- | | Build Plate | Exchangeable continuous-use PEI sheet (∅600 mm) with bajonett catch | | + | | Build Plate | Exchangeable continuous-use PEI sheet (∅476 mm) on vacuum table | |
- | | Filament diameter | 1.75±0.1mm | | + | | Filament diameter | 1.75±0.1mm | |
| Minimum layer resolution | 0.1mm | | | Minimum layer resolution | 0.1mm | | ||
| Positioning accuracy | ±0.1mm | | | Positioning accuracy | ±0.1mm | | ||
| Approx. Tolerance | ±0.2mm | | | Approx. Tolerance | ±0.2mm | | ||
- | |||
- | |||
- | |||
Line 48: | Line 36: | ||
=== Power and Electronics === | === Power and Electronics === | ||
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
- | | Power consumption (total) | approx. 800W | | + | | Power consumption (total) | 3600 W max. | |
- | | Power supply unit | 1050W, 100 … 240V(AC) input\\ with power plug and main switch\\ 13-6.5A\\ 50/60Hz\\ 12V(DC) connector panel | | + | | Power supply unit | 3600 W, 100 … 230 V(AC) input\\ with power plug and main switch\\ 16 A\\ 50/60Hz | |
- | | Drives | 3x 1.2A stepper motor (XYZ positioning drives) | | + | | Drives | 3x 2 A stepper motor (XYZ positioning drives) | |
- | |::: | 2x 1.2A planetary gear drive stepper motor (extruder drives) | | + | |::: | 1x 1.2 A stepper motor (extruder drive) | |
- | | Positioning step-width axes | X=0.028mm\\ Y=0.019mm\\ Z=0.003mm | | + | | Hot end | 24 V, 80 W integrated heating element | |
- | | Hot ends | 12V, 40W integrated heating element per hot end | | + | | Build plate heating | 1000 W wired silicone heating pad | |
- | | Print bed heating | 170W wired silicone heating pad | | + | | Chamber heating | 2000 W heating resistor | |
- | | Chamber heating | 4x 170W heating resistor (two per heating element) | | + | | Chamber lighting | 2x 4 W LED array, 6.500K | |
- | | Chamber lighting | 2x 4W LED array, 6.500K | | + | |
| Stand-alone operating module | integrated capacitive 10” touchscreen controller | | | Stand-alone operating module | integrated capacitive 10” touchscreen controller | | ||
- | | Integrated computer | UDOO Quad Single Board Computer (Quad core 1GHz CPU) | | + | | Integrated computer | Quad core 1GHz CPU | |
- | | Machine control | RADDS v1.5 3D Printer Driver Shield | | + | |
- | | Load switching | 3x High Current Solid State Relais | | + | |
- | | Fans | 3x 119x119x25mm, 12V, 140m³/h axial fan\\ (heat chamber circulation and cooling system) | | + | |
- | |::: | 1x 80x80x25, 12V, 33m³/h axial fan (air filter) | | + | |
=== Sensors === | === Sensors === | ||
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
- | | Limit switch\\ H-frame (X/Y) and print table (Z) | magnetic hall endstops | | + | | Limit switch axes vertical position | inductive poximity endstops | |
- | | Filament end recognition | mechanic limit switch | | + | | Temperature sensors | 800 °C thermocouple | |
- | | Temperature sensors\\ hot ends | 800°C thermocouple | | + | |
- | | Temperature sensors\\ print table, print chamber | 300°C thermistors | | + | |
- | === Air cooling system === | + | === Compressed Air Supply === |
|<75% 40% 60%>| | |<75% 40% 60%>| | ||
- | | Throughput | 80 l/h | | + | | Throughput | 80 l/min | |
- | | Radiator | 120 mm full copper radiator | | + | | Condition | 6-8 bar, dry, oil-free | |
- | | Fan | see [[#power-and-electronics|electronics]] | | + | |
- | | Hose diameter | G1/4” | | + | |
- | | Coolant | Innovatek Protect IP ready-to-use | | + | |
- | | Coolant qty. | approx. 250ml | | + | |
- | + | ||
- | + | ||
- | === Air filter === | + | |
- | |<75% 40% 60%>| | + | |
- | | Air filter | fan duct with exchangeable activated charcoal container | | + | |
- | | Fan | see [[#power-and-electronics|electronics]] | | + | |
- | | Filling | 10g, Ø4mm activated charcoal granules | | + | |
=== Ambient conditions === | === Ambient conditions === |