User Tools

Site Tools


vp75:technical-data

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
vp75:technical-data [2016/12/03 10:59]
Markus Bürgener
vp75:technical-data [2017/01/18 09:21]
Simon Kühling correct build sheet size
Line 1: Line 1:
-===== Technical Data VP75 AMS =====+===== Technical Data VP75 Additive Manufacturing System ​=====
 ==== General / Dimensions / Weights ==== ==== General / Dimensions / Weights ====
 |<75% 40% 60%>| |<75% 40% 60%>|
Line 6: Line 6:
 | Additional features ​    | integrated LED lighting ​ | | Additional features ​    | integrated LED lighting ​ |
 | Length ​                 | 800 mm    | | Length ​                 | 800 mm    |
-| Width                   ​| ​600 mm    | +| Width                   ​| ​800 mm    | 
-| Height ​                 | 800 mm    |+| Height ​                 | 2,200 mm    |
 | Weight ​                 | 250 kg (empty) ​ | | Weight ​                 | 250 kg (empty) ​ |
 | Positioning System ​     | 3-axis delta\\ Automatic three-point leveling ​ | | Positioning System ​     | 3-axis delta\\ Automatic three-point leveling ​ |
 | Manufacturing Technology ​ | Fused Filament Fabrication (FFF)  | | Manufacturing Technology ​ | Fused Filament Fabrication (FFF)  |
-| Compressed Air  | +| Compressed Air  ​| 6-8 bar, dry, oil-free ​|
 | Connection cable        | 1 m\\ 230 V AC Schuko plug\\ IEC 60320 16A connector ​ | | Connection cable        | 1 m\\ 230 V AC Schuko plug\\ IEC 60320 16A connector ​ |
 | Network ​                | Ethernet 10/100, RJ45  | | Network ​                | Ethernet 10/100, RJ45  |
Line 18: Line 18:
 |<75% 40% 60%>| |<75% 40% 60%>|
 | Extrusion Temperature ​     | max. +500°C ​ | | Extrusion Temperature ​     | max. +500°C ​ |
-| Build Plate Temperature ​     | max. +130°C ​ | +| Build Plate Temperature ​     | max. +150°C ​ | 
-| Build Chamber Temperature ​ | max. +70°C   ​+| Build Chamber Temperature ​ | max. +80°C   |
- +
- +
-=== Hot end === +
-|<75% 40% 25% 35%>| +
-| Screwable M6 brass nozzles A/F8 \\ (included in delivery) ​ |  Bore diameter\\ [mm]  |  Recommended layer height\\ First layer / following ​ | +
-|::: |  2x0.25 ​ |  0.25 / 0.10 - 0.20  | +
-|::: |  2x0.35 ​ |  0.35 / 0.10 - 0.28  | +
-|::: |  1x0.50 ​ |  0.50 / 0.20 - 0.40  | +
-|::: |  1x0.75 ​ |  0.60 / 0.25 - 0.60  ​|+
  
  
 === Building Capacities === === Building Capacities ===
 |<75% 40% 60%>| |<75% 40% 60%>|
-| Build Volume ​                | 75 liter\\ Height: ​400 mm\\ Build plate diameter: ​600 mm  |+| Build Volume ​                | 75 liter\\ Height: ​600 mm\\ Build plate diameter: ​400 mm  |
 | Extruder head                | Encapsulated high-temperature single nozzle\\ ​  | | Extruder head                | Encapsulated high-temperature single nozzle\\ ​  |
-| Build Plate                  | Exchangeable continuous-use PEI sheet (∅600 mm) with bajonett catch |  +| Build Plate                  | Exchangeable continuous-use PEI sheet (∅476 mm) on vacuum table |  
-| Filament diameter ​       | 1.75±0.1mm ​  |+| Filament diameter ​           | 1.75±0.1mm ​  |
 | Minimum layer resolution ​    | 0.1mm                                                        | | Minimum layer resolution ​    | 0.1mm                                                        |
 | Positioning accuracy ​        | ±0.1mm ​                                                           | | Positioning accuracy ​        | ±0.1mm ​                                                           |
 | Approx. Tolerance ​           | ±0.2mm ​                                                           | | Approx. Tolerance ​           | ±0.2mm ​                                                           |
- 
- 
- 
  
  
Line 48: Line 36:
 === Power and Electronics === === Power and Electronics ===
 |<75% 40% 60%>| |<75% 40% 60%>|
-| Power consumption (total) ​    ​| ​approx800W  ​+| Power consumption (total) ​    ​| ​3600 W max. | 
-| Power supply unit             ​| ​1050W, 100 … 240V(AC) input\\ with power plug and main switch\\ ​13-6.5A\\ 50/60Hz\\ 12V(DC) connector panel  ​+| Power supply unit             ​| ​3600 W, 100 … 230 V(AC) input\\ with power plug and main switch\\ ​16 A\\ 50/60Hz | 
-| Drives ​                       | 3x 1.2A stepper motor (XYZ positioning drives) ​ | +| Drives ​                       | 3x 2 A stepper motor (XYZ positioning drives) ​ | 
-|::: | 2x 1.2A planetary gear drive stepper motor (extruder ​drives)  ​+|::: | 1x 1.2 A stepper motor (extruder ​drive)  | 
-| Positioning step-width axes   | X=0.028mm\\ Y=0.019mm\\ Z=0.003mm ​              +| Hot end                       24 V80 W integrated heating element ​   | 
-| Hot ends                      ​12V40W integrated heating element ​per hot end    | +Build plate heating ​          ​1000 W wired silicone heating pad                   | 
-Print bed heating ​            ​170W wired silicone heating pad                   | +| Chamber heating ​              ​| ​2000 W heating resistor ​ 
-| Chamber heating ​              ​| ​4x 170W heating resistor ​(two per heating element) ​+| Chamber lighting ​             | 2x 4 W LED array, 6.500K ​                                    |
-| Chamber lighting ​             | 2x 4W LED array, 6.500K ​                                    |+
 | Stand-alone operating module ​ | integrated capacitive 10” touchscreen controller ​ | | Stand-alone operating module ​ | integrated capacitive 10” touchscreen controller ​ |
-| Integrated computer ​          ​| ​UDOO Quad Single Board Computer (Quad core 1GHz CPU  | +| Integrated computer ​          | Quad core 1GHz CPU   |
-| Machine control ​              | RADDS v1.5 3D Printer Driver Shield ​ | +
-| Load switching ​               | 3x High Current Solid State Relais ​ | +
-| Fans                          | 3x 119x119x25mm,​ 12V, 140m³/h axial fan\\ (heat chamber circulation and cooling system) ​ | +
-|:::  | 1x 80x80x25, 12V, 33m³/h axial fan (air filter) ​ | +
  
 === Sensors === === Sensors ===
 |<75% 40% 60%>| |<75% 40% 60%>|
-| Limit switch\\ H-frame (X/Y) and print table (Z)                   magnetic hall endstops ​ | +| Limit switch ​axes vertical position ​         ​inductive poximity ​endstops ​ | 
-| Filament end recognition ​                                          | mechanic limit switch ​ | +| Temperature sensors ​               800 °C thermocouple ​ |
-| Temperature sensors\\ hot ends  ​800°C ​thermocouple ​ | +
-| Temperature sensors\\ print table, print chamber ​ | 300°C thermistors ​ |+
  
-=== Air cooling system ​===+=== Compressed ​Air Supply ​===
 |<75% 40% 60%>| |<75% 40% 60%>|
-| Throughput ​    | 80 l/ | +| Throughput ​    | 80 l/min  | 
-Radiator ​      120 mm full copper radiator ​ | +Condition ​    6-8 bar, dry, oil-free  |
-| Fan            | see [[#power-and-electronics|electronics]] ​ | +
-| Hose diameter ​ | G1/​4” ​ | +
-| Coolant ​       | Innovatek Protect IP ready-to-use ​ | +
-| Coolant qty.   | approx. 250ml  | +
- +
- +
-=== Air filter === +
-|<75% 40% 60%>| +
-| Air filter ​ | fan duct with exchangeable activated charcoal container ​ | +
-| Fan         | see [[#​power-and-electronics|electronics]] ​ | +
-| Filling ​    | 10g, Ø4mm activated charcoal granules ​ | +
  
 === Ambient conditions === === Ambient conditions ===
vp75/technical-data.txt · Last modified: 2017/01/18 09:21 by Simon Kühling